2910119 DC/DC converters – QUINT4-PS/24DC/24DC/5/PT
Roll over image to zoom in
AED 650.84 AED
- Primary-switched DC/DC converter
- QUINT POWER
- DIN rail mounting
- SFB Technology (Selective Fuse Breaking)
- Push-in connection
- input: 24 V DC
- output: 24 V DC / 5 A
Input data
Input voltage range | 18 V DC … 32 V DC |
---|---|
Electric strength, max. | 35 V DC (60 s) |
Typical current consumption | 6.9 A (24 V DC) |
Mains buffering | typ. 14 ms (24 V DC) |
Switch-on time | < 1 s |
Typical response time | 300 ms (from SLEEP MODE) |
Inrush current limitation typical | 1 A |
Inrush current integral (I2t) | < 0.05 A2s |
Input fuse | 15 A (slow-blow, internal) |
Input connection data
Connection method | Push-in connection |
---|---|
Stripping length | 10 mm |
Conductor cross section solid | 0.2 mm² … 6 mm² |
Conductor cross section flexible | 0.2 mm² … 6 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.2 mm² … 4 mm² |
Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) | 0.2 mm² … 4 mm² |
Conductor cross section AWG | 24 … 10 |
Output data
Nominal output voltage (UN) | 24 V DC |
---|---|
Setting range of the output voltage (USet) | 24 V DC … 29.5 V DC (> 24 V DC, constant capacity) |
Nominal output current (IN) | 5 A |
Static Boost (IStat.Boost) | 6.25 A |
Dynamic Boost (IDyn.Boost) | 10 A (5 s) |
Selective Fuse Breaking (ISFB) | 30 A (15 ms) |
Magnetic circuit breaker tripping | A1 … A4 / B2 / C1 … C2 / Z1 … Z4 |
System deviation, static | < 1 % (change in load, static 10 % … 90 %) |
System deviation, dynamic | < 3 % (Dynamic load change 10 % … 90 %, 10 Hz) |
System deviation, input voltage change | < 0.1 % (change in input voltage ±10 %) |
Short-circuit-proof | yes |
No-load proof | yes |
Residual ripple | < 10 mVPP |
Connection in parallel | yes, for redundancy and increased capacity |
Connection in series | yes |
Feedback voltage resistance | ≤ 35 V DC |
Protection against overvoltage at the output (OVP) | ≤ 32 V DC |
Rise time | < 1 s (UOUT (10 % … 90 %)) |
Output connection data
Connection method | Push-in connection |
---|---|
Stripping length | 10 mm |
Conductor cross section solid | 0.2 mm² … 6 mm² |
Conductor cross section flexible | 0.2 mm² … 6 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.2 mm² … 4 mm² |
Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) | 0.2 mm² … 4 mm² |
Conductor cross section AWG | 24 … 10 |
Additional information
Input Voltage | 24 V DC |
---|---|
Output Voltage | 24 V DC / 5 A |
Connection | Push-in connection |
Technology | Selective Fuse Breaking |
Unit | DC/DC converter |
-
AED 28.50 – AED 32.50 AED
-
AED 13.00 AED
-
AED 10.00 AED
-
AED 14.00 AED