2909531 Relay Module – PLC-RPT-12DC/21HC/EX
Roll over image to zoom in
AED 68.90 AED
- Datasheet
- PLC-INTERFACE
- consisting of DIN-rail-mountable basic terminal block in 14 mm with Push-in connection and plug-in relay with 10 A power contact
- 1 changeover contact
- 12 V DC input voltage
- Approved according to ATEX/IECEx (Zone 2) and Ex Zone Class I
- Div. 2
- Price@1modules
Coil side
Nominal input voltage UN | 12 V DC |
---|---|
Typical input current at UN | 33 mA |
Typical response time | 8 ms |
Typical release time | 10 ms |
Protective circuit | Reverse polarity protection Polarity protection diode |
Free-wheeling diode Damping diode | |
Operating voltage display | Yellow LED |
Power dissipation for nominal condition | 0.4 W |
Connection data- coil side
Connection name | Coil side |
---|---|
Connection method | Push-in connection |
Stripping length | 8 mm |
Conductor cross section solid | 0.14 mm² … 2.5 mm² |
Conductor cross section flexible | 0.14 mm² … 2.5 mm² |
0.2 mm² … 2.5 mm² (Single ferrule) | |
2x 0.5 mm² … 1 mm² (TWIN ferrule) | |
Conductor cross section AWG | 26 … 14 |
Contact side
Contact type | 1 changeover contact |
---|---|
Type of switch contact | Single contact |
Contact material | AgNi |
Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC… or …FBST 500…) |
Minimum switching voltage | 12 V AC/DC |
Min. switching current | 100 mA |
Maximum inrush current | 30 A (300 ms) |
Limiting continuous current | 10 A |
6 A (value applies to connections 12. If connections 12 are bridged, the normal value applies.) | |
Interrupting rating (ohmic load) max. | 240 W (at 24 V DC) |
58 W (at 48 V DC) | |
48 W (at 60 V DC) | |
50 W (at 110 V DC) | |
80 W (at 220 V DC) | |
2500 VA (for 250 V AC) | |
Interrupting rating (ohmic load) max. bridged | 144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.) |
1500 VA (for 250 V AC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.) | |
Switching capacity | 2 A (at 24 V, DC13) |
0.2 A (at 110 V, DC13) | |
0.2 A (at 250 V, DC13) | |
6 A (at 24 V, AC15) | |
6 A (at 120 V, AC15) | |
6 A (at 250 V, AC15) |
Connection data:-Contact side
Connection name | Contact side |
---|---|
Connection method | Push-in connection |
Stripping length | 8 mm |
Conductor cross section solid | 0.14 mm² … 2.5 mm² |
Conductor cross section flexible | 0.14 mm² … 2.5 mm² |
0.2 mm² … 2.5 mm² (Single ferrule) | |
2x 0.5 mm² … 1 mm² (TWIN ferrule) | |
Conductor cross section AWG | 26 … 14 |
Additional information
Approvals | EAC Ex IECEx cUL Listed UL Listed |
---|---|
Contact type | 1 changeover contact |
Input voltage | 12 V DC |
Contact material | AgNi |
Type of switch contact | Single contact |
Width | 1.4cm |
Height | 8cm |
Depth | 9.4cm |
-